PVC compound grade O-40, receipt OM-40 is produced under GOST 5960-72 as black, white (snow white) and natural granules. It’s meant for sheathing of cables and wires used in the -40 °С to +70 °С range. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm · cm, not less |
5·1010 |
2 |
Tensile strength, MPa (kg/cm²), not less |
11.7 (120) |
3 |
Elongation at break, %, not less |
300 |
4 |
Brittle point, °C, not more |
-40 |
5 |
Density, g/cm³, not more |
1.4 |
6 |
Hardness at 20 °C, MPa (kgf/cm²), within the range |
0.88 1.96 (9 20) |
7 |
Combustibility, oxygen index, %, not less |
21 |
PVC compound grade I40-13A, receipt 8/2 is produced under GOST 5960-72 as natural granules and it is meant for insulation of cables and wires used in the -40 °С to +70 °С range.. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm · cm, not less |
5 · 1013 |
2 |
Tensile strength, MPa (kg/cm²), not less |
19.6 (200) |
3 |
Elongation at break, %, not less |
250 |
4 |
Brittle point, °C, not more |
-40 |
5 |
Density, g/cm³, not more |
1.28 1.32 |
6 |
Elongation at break after ageing at 100 ± 2 °C within 7 days, %, not less |
80 |
7 |
Light stability at 70 °C, hours, not less |
1000 |
8 |
Hardness at 20 °C, MPa (kgf/cm²), within the range |
1.56 – 2.15 (16 – 22) |
PVC compound with low combustibility is produced under manufacturer’s TU as black and natural granules, it has the following grades: NGP 30-32, NGP 40-32, NGP 50-32, NGP 55-32. It is meant for sheathing of cables and wires used in the -70 °С to +70 °С range and in increased fire hazard conditions. See technical characteristics.
# |
Item |
Standard |
NGP 55-32 |
NGP 50-32 |
NGP 40-32 |
NGP 30-32 |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
1 · 1012 |
1 · 1012 |
1 · 1012 |
1 · 1012 |
2 |
Tensile strength, MPa, not less |
16 |
16 |
17 |
18 |
3 |
Elongation at break, %, not less |
280 |
280 |
280 |
250 |
4 |
Elongation at break after ageing at 100 ± 2 °C within 7 days, %, not less |
80 |
80 |
85 |
85 |
5 |
Brittle point, °C, not more |
-55 |
-50 |
-40 |
-30 |
6 |
Weight loss at 160 °C within 6 h., %, not more |
2 |
2 |
2 |
2 |
7 |
Hardness Shoe А, points, not less |
70 |
70 |
70 |
75 |
8 |
Density, g/cm³, not less |
1.5 |
1.5 |
1.5 |
1.5 |
9 |
Flammability OI (oxygen index), %, not less |
32 |
32 |
32 |
32 |
10 |
Water absorption, %, not more |
0.2 |
0.2 |
0.2 |
0.2 |
Chalk filled PVC compound grade OM 20-12 is produced under TU 2246-038-10641390-2008 as natural granule and it can be coloured at the customer’s request. It is meant for insulation and sheathing applied by extrusion method. The cables and wires with such sheathing and insulation correspond to DIN VDE 0250 p.204. Chalk filled PVC compound grade IM 30-13 is produced under TU 2246-038-10641390-2008 as natural granules. It is meant for insulation and sheathing applied by extrusion method. The cables and wires with such insulation and sheathing correspond to VDE 0250 p.204. In terms of quality grades IM 30-13 and OM 20-12 are the same as grades YI1 (TI 1) and YM1 (TM 1) under DIN VDE 0207. See technical characteristics.
# |
Item |
Standard |
OM 20-12 |
IM 30-13 |
1 |
Specific volume resistivity, Ohm·cm, not less - at 20 °C - at 70 °C |
1·1012 1·1011 |
1·1013 1·1011 |
2 |
Tensile strength, MPa, not less |
13.0 |
14.0 |
3 |
Elongation at break, %, not less |
230 |
250 |
4 |
Mechanical characteristics after ageing within 7 days at 80 ± 2 °C: - Tensile strength variation, %, not more - Elongation at break variation, %, not more |
± 20 ± 20 |
± 20 ± 20 |
5 |
Brittle point, °C, not more |
-20 |
-30 |
6 |
Weight loss at 160 °C within 6 h., %, not more |
2 |
2 |
7 |
Hardness at 20 °C, MPa (kgf/cm²), within the range |
2.26 3.05 (23 31) |
1.47 2.16 (15 22) |
8 |
Hardness Shore А, points, not less |
80 90 |
85 90 |
9 |
Density, g/cm³, not more |
1.56 1.62 |
1.45 1.55 |
10 |
Flammability OI (oxygen index), %, not less |
23 |
23 |
11 |
Water absorption, %, not more |
0.4 |
0.4 |
PVC compound grade O-50 is produced under GOST 5960-72 as black granules. It is meant for sheathing of cables and wires used in the -50 °С to +70 °С range. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm · cm, not less |
1 · 1010 |
2 |
Tensile strength, MPa, not less |
15.7 |
3 |
Elongation at break, %, not less |
280 |
4 |
Brittle point, °C, not more |
-50 |
5 |
Density, g/cm³, not more |
1.25 1.31 |
6 |
Hardness at 20 °С, MPa (kgf/cm²), within the range |
10 – 16 (0.98 – 1.57) |
7 |
Combustibility OI (oxygen index), %, not less |
– |
8 |
Water absorption, %, not more |
0.3 |
PVC compound grade O-55 is produced under GOST 5960-72 as black granules. It is meant for sheathing of cables and wires used in the -55 °С to +70 °С range. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
1·1010 |
2 |
Tensile strength, MPa, not less |
11.7 |
3 |
Elongation at break, %, not less |
350 |
4 |
Brittle point, °C, not more |
-55 |
5 |
Density, g/cm³, not more |
1.18 – 1.25 |
6 |
Hardness at 20 °С, MPa (kgf/cm²), within the range |
7 – 11 (0.69 – 1.07) |
7 |
Weight loss at 1 60 ± 2 °С within 6 h, %, not more |
2 |
8 |
Water absorption, %, not more |
0.3 |
9 |
Flammability OI (oxygen index), %, not less |
21 |
PVC compound grade O-65 is produced under TU 6-01-1324-86 as black granules. It is meant for sheathing of cables and wires used in the -65 °С to +70 °С range. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
1·108 |
2 |
Tensile strength, MPa, not less |
14 |
3 |
Elongation at break, %, not less |
300 |
4 |
Brittle point, °C, not more |
-65 |
5 |
Density, g/cm³, not more |
1.25 |
6 |
Tear strength, kgf/cm², not less |
54 |
7 |
Softening point, °C |
170 ± 10 |
8 |
Water absorption, %, not more |
0.4 |
PVC compound grade I50-13 is produced under GOST 5960-72 as natural granules. It is meant for insulation of cables and wires used in the -50 °С to +70 °С range. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
2 · 1013 |
2 |
Specific volume resistivity at 70 °C, Ohm·cm, not less |
5 · 1010 |
3 |
Tensile strength, MPa, not less |
19.6 |
4 |
Elongation at break, %, not less |
200 |
5 |
Brittle point, 0 °C, not more |
-50 |
6 |
Density, g/cm³, not more |
1.29 – 1.35 |
7 |
Elongation at break after ageing at 100 ± 2 °C within 7 days, %, not less |
80 |
8 |
Light stability at 70 °C, hours, not less |
1000 |
9 |
Weight loss at 160 °C within 6 hours, %, not more |
2 |
PVC compound grade I60-12 is produced under GOST 5960-72 as natural granules. It is meant for insulation of cables and wires used in the -60 °С to +70 °С range. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
1 · 1012 |
2 |
Specific volume resistivity at 70 °C, Ohm · cm, not less |
1 · 1010 |
3 |
Tensile strength, kgf/cm², not less |
100 |
4 |
Elongation at break, %, not less |
300 |
5 |
Brittle point, °C, not more |
-60 |
6 |
Density, g/cm³, not more |
1.16 1.24 |
7 |
Elongation at break after ageing at 100 ± 2 °C within 7 days, %, not less |
80 |
8 |
Weight loss at 160 °C within 6 h., %, not more |
3.0 |
9 |
Flammability (А method), sec., not more |
30 |
10 |
Water absorption, %, not more |
0.46 |
11 |
Softening point, °C |
175 ± 10 |
PVC compound grade IT-105 is produced under GOST 5960-72 as natural granules. It is meant for thin insulation of auto wires, and sheathing of other heat-resistant cables used in the -40 °С to +105 °С range. The compound can be produced without lead content at the customer’s request. See technical characteristics.
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
2 · 1013 |
2 |
Specific volume resistivity at 105 °C, Ohm·cm, not less |
1 · 1011 |
3 |
Tensile strength , МPа, not less |
14.7 |
4 |
Elongation at break, %, not less |
350 |
5 |
Brittle point, °C, not more |
-40 |
6 |
Density, g/cm³, not more |
1.21 1.27 |
7 |
Hardness at 20 °C, MPa, not less |
1.17 |
8 |
Hardness at 70 °C, MPa, not less |
0.39 |
9 |
Flammability, sec., not more |
15 |
10 |
Weight loss at 160 °C within 6 h., %, not more |
1.5 |
11 |
Water absorption, %, not more |
0.2 |
Low fire hazard compound type PP is thermoplastic granulated material, it is produced under manufacturer’s TU and has three grades: PPO 30-35 (sheathing), PPI 30-30 (insulation), PPV-28 (material filling). It is meant for sheathing of cables and wires used in areas with higher requirements to fire safety and flame propagation if the cables are laid in bunches, in areas with higher requirement to low smoke and chloride hydride emission at combustion. This compound is also meant for cables used at atomic, heat and hydro power stations, in the underground, high buildings, on shipboard, at chemical plants, in warehouses and others. See technical characteristics:
- PPO 30-35 (sheathing);
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
5 · 1011 |
2 |
Tensile strength, MPa, not less |
11 |
3 |
Elongation at break, %, not less |
250 |
4 |
Brittle point, °C, not more |
-30 |
5 |
Density, g/cm³, not more |
1.61 |
6 |
Hardness Shoe А, points, not less |
88 |
7 |
Mass fraction of chlorine hydride at combustion, %, not more |
14 |
8 |
Flammability OI (oxygen index), %, not more |
35 |
9 |
Maximum smoke density at combustion, Dm, not more |
200 |
- PPI 30-30 (insulation);
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm · cm, not less |
5·1013 |
2 |
Tensile strength, MPa, not less |
15 |
3 |
Elongation at break, %, not less |
250 |
4 |
Brittle point, °C, not more |
-30 |
5 |
Density, g/cm³, not more |
1.52 |
6 |
Hardness Shoe А, points, not less |
80 |
7 |
Mass fraction of chlorine hydride at combustion, %, not more |
13 |
8 |
Flammability OI (oxygen index), %, not more |
30 |
9 |
Maximum smoke density at combustion, Dm, not more |
280 |
- PPV-28 (material filling).
# |
Item |
Standard |
1 |
Specific volume resistivity at 20 °C, Ohm·cm, not less |
- |
2 |
Tensile strength, MPa, not less |
3 |
3 |
Elongation at break, %, not less |
200 |
4 |
Brittle point, °C, not more |
- |
5 |
Density, g/cm³, not more |
1.9 |
6 |
Hardness Shoe А, points, not less |
- |
7 |
Mass fraction of chlorine hydride at combustion, %, not more |
5 |
8 |
Flammability OI (oxygen index), %, not more |
28 |
9 |
Maximum smoke density at combustion, Dm, not more |
150 |
All the compounds grades are packed in special soft “Big-Bag” containers for single use. The containers have a polyethylene inner coating for bulk goods. The weight of goods in a container is from 600 kg to 1'000 kg. Smaller batches can be supplied in 25 kg paper bags. The compounds are transported by any vehicles secured the goods quality till they are delivered to the customer.
Tel./fax: +7 (4922) 33-90-08 and 33-62-99
E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Head of Cable Department
Dmitry S. Blinov
+7 (915) 790-17-40 and (930) 749-11-15
E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Skype: ksk-blinov
Leading Manager
Elena G. Garanina
+7 (915) 760-67-45 and (920) 938-63-18
E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Skype: ksk-garanina
Manager
Ekaterina V. Gorshkova
+7 (915) 767-17-08 and (920) 620-77-78
E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Skype: ksk-gorshkova
Manager
Alexander I. Muratov
+7 (910) 777-40-75 and (930) 749-11-16
E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Skype: ksk-muratov
|
|